General description
This special penetrant testing line is designed especially for aircraft parts.
The equipment is of a fixed electromechanical split XY structure and mainly composed of such parts as a power control cabinet, DC magnetization power source,man-machine interface operation control, magnetizing and holding devices to X axle direction and magnetizing and holding devices to Y axle direction, AC magnetizing power source, AC-DC converter, X axle and Y axle converters, electric control system, magnetic suspension and recovery system, demagnetization system, dark room, fluorescent and day-light illumination devices.
As the equipment is controlled by industrial PLC for magnetizing current and time and demagnetizing frequency and time, detection accuracy is greatly increased and both magnetization and demagnetization can be finished automatically.
The equipment features stability and reliability, simple operation, high detection efficiency and low labor intensity. It is suited for detecting by the wet magnetic-particle process all the cracks or fine defects on the surface and near-surface of components made of magnetic iron materials due to raw materials, forging, casting, quenching, machining and fatigue.

Mode of magnetization

Circumferential, longitudinal and combined magnetization

Circumferential magnetizing current

Effective value of AC 0-6000A, continuously adjustable, digital display with power failure phase control;

Longitudinal magnetizing potential

Effective value of DC 0-12000AT, continuously adjustable, digital display with power failure phase control;

Temporary loading rate

≥25%

Electrode separation

0-1500mm, electrically-driven and adjustable

Longitudinal magnetizing potential in Y axle direction

DC 0~36000AT(average value), continuous and adjustable; one coil of 6 turns and two coils of 12 turns with working size of cave: 700 mm×700 mm

Detection sensitivity

Magnetic track can be displayed clearly on the AC standard reference block and high-sensitivity test piece, and test results of a DC annulus reference block should conform to the requirement

Mode of demagnetization

automatic attenuation demagnetization

Demagnetization effect

≤0.3mT (Standard Test Block)

UV intensity of illumination

UV intensity of illumination at 380mm from the work piece ≥4000μW/cm2

Power source

3-phase 5-wiere system with 380V± 10%, 50Hz;

Working Environment

Temperature -5℃~+55℃,RH≤90%.

The equipment is of a fixed electromechanical split XY structure and mainly composed of such parts as a power control cabinet, DC magnetization power source,man-machine interface operation control, magnetizing and holding devices to X axle direction and magnetizing and holding devices to Y axle direction, AC magnetizing power source, AC-DC converter, X axle and Y axle converters, electric control system, magnetic suspension and recovery system, demagnetization system, dark room, fluorescent and day-light illumination devices.

Special Penetrant Testing Line of Aircraft Parts

Special Penetrant Testing Line of Aircraft Parts

Special Penetrant Testing Line of Aircraft Parts

Special Penetrant Testing Line of Aircraft Parts

Get Price And Support

Simply complete the form below, click submit, you will get the price list and a representative will contact you within one business day. Please also feel free to contact us by email or phone.